Being one of the fundamental and most used
instruments, oscilloscopes have many advantages over traditional optical
multimeters. The basic difference is that DMMs can only calculate instantaneous
reading. However, there is a need to get deep insights into a component's
functioning over a certain period of time in several instances. They are also
used in an electronic device's troubleshooting and debugging. Although
oscilloscopes appear to measure voltage only but can provide a number of
parameters such as peak-to-peak levels, RMS values, frequency, and phase timing
parameters, there are several other measurement forms that can be calculated,
as you can see in later sections of this article.
The fluke portable handheld device with four-channel and up to 500MHz
allows a faster sample rate and is capable of capturing unknown waveforms on
display.
FEATURES:
·
Internally Isolated
Inputs
·
1000v Safety Rated
Cat Iii Cables
·
6000v Safety Rated
Cat Iv Cables
·
Multiple Bandwidth
Model Range
·
5gs/S Sampling Rate
·
200ps Resolution Rate
·
Memory With A 10k
Samples Per Channel
·
Digital Counter With
999 Limits
TESTS and EXPERIMENTS:
Probe Settings And Input Channel
Selection:
To select a probe, follow the steps below:
1- Display the input A key labels and open them.
2- Select the probe type as Current, Voltage,
or Temperature.
3- To select the input channel, select from A,
B, C, or D, and then the respective channel will switch ON.
Displaying Unknown Signal:
To display unknown signal onto the screen,
use the following steps:
1- Use the AUTO feature, and the signal will
appear on the screen.
2- Alternatively, manual selection can be made
by pressing the AUTO button again.
3- Use arrow keys to select RANGE, TIME, and
MOVE.
Automatic Scope Measurements:
1- Use the SCOPE label.
2- Navigate to the READING menu and select the
reading number to be displayed.
3- Each reading number is associated with a different
measurement. Select accordingly.
Acquiring Waveforms:
1- Display SCOPE label keys.
2- Open the WAVEFORM OPTIONS menu and select”
Acquisition”.
3- Select from FAST, FULL, or NORMAL options.
4- Exit the menu.
Reversing Waveform Polarity:
1- Select INPUT A key label and open it.
2- Select INVERTED and accept the inverted
waveform.
3- Exit the menu.